Every always-on box and both office workstations sit behind a TP-Link Tapo P115 smart plug. Home Assistant reads watts from each plug, integrates them into kWh, prices that against the live time-of-use electricity rate, and exposes the result to Grafana. This page is the map of what is metered, how it is grouped, what it costs, and how to add a plug.

What is metered

Plug (HA device) Entity prefix Group What it powers
Threadripper Host threadripper_* homelab Threadripper 2950X/X399 host (192.168.10.14): GPU worker + general worker VMs, 2× RTX 3090
NAS Drive PSU nas_psu_* homelab The drive-shelf PSU for the NAS
TrueNAS (DL360) truenas_* homelab The TrueNAS/DL360 host itself (192.168.10.133)
HP SFF + Optiplex hp_sff_* homelab HP 8500 SFF (.21). The plug name still says Optiplex; that host is retired
HP Elite Mini G9 hp_elite_* homelab HP Elite Mini 600 G9 (.22)
Gaming PC gaming_pc_* office 7800X3D workstation. Not a cluster node; the two AI RTX 3090s are on Threadripper
MacBook + Monitor macbook_* office Office desk
Shed Lab (solar) shed_lab_* none HP micro in the shed (.20), solar-fed

Shed Lab runs off the shed's own solar and battery bank, so it has watts and kWh (with the daily/weekly/monthly/yearly meters) but no cost entities, and it is not in any group or in the house-share numbers. Its supply side (MPPT yield, battery bank voltage and state of charge) lives in the Grafana Solar dashboard (shed-solar).

Household plugs (dryer, TV, office lamps, the garage fridge) exist in Home Assistant but are outside this accounting: the Prometheus filter only exports the prefixes above.

Groups

Group Members Use it for
homelab_* The five always-on servers The number to compare against the bill
office_* Gaming PC + MacBook Workstations. Metered and priced, but not locked on, so expected to swing to zero
combined_* Everything Total household draw from metered plugs

Each group has <group>_total_power, <group>_total_energy (with daily/weekly/monthly/yearly meters), <group>_cost_rate, <group>_cost (same meters), and the finished-period sensors below.

How cost is computed

device watts ──integration──▶ kWh ──utility_meter──▶ daily / weekly / monthly / yearly kWh
      │
      └──× current all-in rate──▶ USD/h ──integration──▶ USD ──utility_meter──▶ daily / … / yearly USD

The all-in marginal rate is (energy + delivery riders) × (1 + sales tax). The energy component steps between three windows:

Window When All-in rate
Summer on-peak June–August, weekdays 14:00–19:00 ~$0.285
Summer off-peak June–August, all other hours ~$0.235
Non-summer September–May ~$0.213

Rates live in my-apps/home-automation/home-assistant/configuration.yaml under input_number:. Git is the source of truth: the initial: values reset the UI sliders on every Home Assistant restart, so a permanent rate change goes in the file, not the dashboard.

Cost integrates a live USD/hour rate rather than applying a flat tariff after the fact, so a workload that runs only during on-peak hours is priced at on-peak rates.

Finished periods

The *_monthly sensors are month-to-date and reset on the 1st, so they are the wrong thing to compare against a bill. Home Assistant's utility_meter keeps the previous cycle in a last_period attribute, and template sensors surface it:

Sensor What it holds
sensor.<group>_cost_last_month Last calendar month's finished total
sensor.<group>_total_energy_last_month Last month's kWh
sensor.<group>_cost_yesterday Yesterday's finished cost
sensor.<prefix>_cost_last_month Per-device, last month
sensor.<prefix>_energy_last_month Per-device, last month

These stop moving once the cycle closes. Compare today-so-far with yesterday only as partial versus complete totals. Missing previous-period data is shown as unavailable. A smaller partial-day total does not establish a saving.

Where to look

Surface What it is
Grafana Power & Cost (homelab-power-cost, folder Home & Energy) Mirrors HA's Overview/Devices/House views: draw, cost today/month/year, per-device table, 14-day trends, and per-plug volts/amps in a collapsed row
Grafana Gaming PC (gaming-pc) and Cooling (ac-cooling) Mirror HA's Gaming and Cooling views, with 14-day per-day history
Home Assistant Homelab Power dashboard Overview, Daily spend, Bill breakdown, Rates & savings, Devices, House, Solar, Gaming, Cooling, and Settings
HA Energy dashboard Configured in the UI; each sensor.<prefix>_energy is an Individual device

How Grafana names a plug

The dashboards do not carry a device list. Every query selects the entity IDs for its group and derives the display name from the metric's friendly_name label by stripping the trailing metric words (Power, Energy, Cost, Voltage, Current, Share). That is why customize.yaml sets every friendly name to <Device> <Metric ...>, and why a device display name must not itself contain one of those words.

Reading the numbers

The idle floor is the bill. Peak draw is brief; the 24-hour minimum runs 8,760 hours a year. When the Baseline Cost / Year panel accounts for most of Cost This Year, workload tuning will not move the number. Only removing or consolidating hardware does.

Run-rate panels are what-ifs, not forecasts. Run-Rate / Year and Cost / Year If Left At This Draw annualise the current instant to answer "what does leaving this on cost me?". Use Cost This Month or Cost Last Month for a bill estimate.

The HP SFF plug cannot be attributed. It feeds two hosts. Split the outlet before concluding which of the two to retire.

House-level data from Consumers Energy

The plugs only see the homelab. The whole-house number comes from the utility: a daily CronJob (my-apps/home-automation/consumers-energy-sync/) drives a headless Chromium through the Consumers Energy portal, downloads the Share data → CSV export (one row per day, trailing 30 days, with CE's own cost), and pushes it into Home Assistant. Source and image: github.com/mitchross/consumers-energy-sync.

What lands Where it shows
consumers_energy:grid_kwh, consumers_energy:grid_cost (long-term statistics) HA Energy dashboard grid source with cost; statistics-graph cards
sensor.consumers_energy_kwh_yesterday, _kwh_7d, _kwh_month, _kwh_last_month and the _cost_* twins Homelab Power dashboard, Grafana via the Prometheus exporter
sensor.homelab_share_of_house, sensor.combined_share_of_house Homelab kWh yesterday as a share of the house
sensor.consumers_energy_effective_rate CE cost / kWh yesterday, next to the modelled rate

The importer sets nine live sensors through the REST API, including sensor.consumers_energy_last_reading. Those states normally disappear on an HA restart even though recorder history and statistics persist. The local consumers_energy_restore integration restores the last recorded values after HA starts. Its source lives in scripts/consumers-energy-restore/ and the config copier installs it under /config/custom_components/consumers_energy_restore.

Recovery reads the SQLite recorder in a worker thread and preserves the original reading date. It requires all nine recorded states and skips recovery if a newer import has already populated any of them. Missing or invalid history leaves the comparisons unavailable until the next successful daily import at 13:17. Derived rates and shares recompute from the restored inputs. This integration assumes the current local SQLite recorder; revisit it if the recorder moves to another database backend.

Running it elsewhere. The same image runs anywhere with the same env vars (CE_PORTAL_USERNAME, CE_PORTAL_PASSWORD, HASS_URL, HASS_TOKEN):

# local checkout: node --env-file=.env index.mjs [--download-only|--import-only|--dry-run]
docker run --rm --user 1001:1001 --env-file .env -v ce-data:/data \
  ghcr.io/mitchross/consumers-energy-sync:v0.1.4

/data holds the Playwright cookie jar (a credential) and the CSVs; keep it private. The first run logs in with the password; later runs reuse the cookie jar. A failed run leaves a full-page screenshot in /data.

Cumulative sums. Each import bases its running total on what HA already holds just before the export window, so overlapping trailing windows stay consistent. Importing data older than what HA has breaks that: clear both statistics first (recorder.clear_statistics) and import oldest-first.

Releasing a new image. Tag the sync repo (git tag v0.x.y && git push --tags); the workflow publishes to GHCR. Bump the tag and digest in cronjob.yaml. The base image version must equal the playwright version in package.json.

Safety: the power-off lockout

The Homelab plug power-off lockout automation turns any homelab plug back on if it is switched off and raises a persistent notification. It covers the five homelab plugs. The office plugs are deliberately excluded: those machines are meant to be powered down.

Hiding a switch via customize.yaml is cosmetic only; the automation is the real enforcement. To intentionally power-cycle a plug, disable the automation first.

The automation triggers on switch entity IDs (switch.threadripper, switch.hp_sff, …). A typo there fails silently: the automation loads fine and simply never fires. Verify a change against Developer Tools → States before trusting it.

Adding a plug

  1. Adopt the plug in the Tapo app, then add it to Home Assistant through the TP-Link integration. Rename the device in HA to the display name you want, then rename its entities so they share one short prefix (sensor.<prefix>_current_consumption, switch.<prefix>, …). The prefix is permanent: renaming it later orphans every statistic recorded under it.
  2. In my-apps/home-automation/home-assistant/configuration.yaml, add sensor.<prefix>_* to prometheus.filter.include_entity_globs, then add its energy integration, cost integration, four energy utility_meters, four cost utility_meters, a *_cost_rate template, *_cost_last_month and *_energy_last_month templates, and a *_power_share template. Add it to the Total Power template of its group and of combined.
  3. Add friendly_name entries in customize.yaml (<Device> <Metric ...> form), and the switch to the lockout automation if the device must stay on.
  4. Add it to lovelace-homelab-power.yaml, and to the entity regex of the per-plug queries in both Grafana dashboards under monitoring/metrics/prometheus-stack/dashboards/. Those are plain .json files assembled into ConfigMaps by configMapGenerator; edit the .json, never a rendered manifest.
  5. Add sensor.<prefix>_energy as an Individual device on the HA Energy dashboard.

The name: slug must equal the entity prefix. Home Assistant derives the entity ID from name:, so name: "HP SFF Energy" produces sensor.hp_sff_energy. If the slug drifts, every template and dashboard reference silently reads nothing: no error, just empty panels.

Changes reach the pod through hashed ConfigMaps and an initContainer that copies files onto the PVC. A merged PR changes the pod's ConfigMap references, so ArgoCD automatically performs a Recreate rollout. This briefly interrupts Home Assistant. Do not copy config into the live PVC or manually restart the Deployment to publish changes. Revert dashboard/config changes through a PR.

Verify afterwards:

# the new sensors exist and are numeric
kubectl exec -n home-assistant deploy/home-assistant -c home-assistant -- \
  sh -c 'wget -q -O- http://127.0.0.1:8123/api/prometheus | grep <prefix>_energy_daily'

Newly created integrations and utility meters start at zero. Totals only fill in as data accumulates; an empty panel on day one is expected, not a bug.

Daily comparisons and bill allocation

Daily spend puts group and per-plug dollars and kWh beside yesterday's completed totals. Previous-day values come from each daily utility meter's last_period, checked against its local last_reset date. Segmented bars show how the tracked loads contribute to cost; the Devices view does the same for watts. The graph cards fill their sections on desktop and collapse on phones.

Bill breakdown separates energy share from estimated cost share. Its non-overlapping buckets are homelab, office, modeled cooling, and the remainder. Gaming is already in office. The solar shed is never included. Cost remainder also contains the difference between the configured marginal rate and CE's reported cost; it is not a measured appliance load. Negative remainders stay visible so a model mismatch cannot masquerade as perfect attribution.

power-insights.yaml holds these derived sensors. House comparisons are only available when consumers_energy_last_reading equals yesterday's local date and both utility totals exist. A late report or missing recovery history produces unavailable comparisons, not zero consumption. Startup recovery preserves the report date, so an old report cannot pass the freshness check.

Rates & savings translates a constant load into dollars/day and dollars/30 days at the configured current rate. These are what-if calculations, not bill forecasts or newly verified utility tariffs. Fixed monthly fees are excluded. The three rate windows and permanent GitOps rate settings remain unchanged.

Local AI power brief

The Overview includes hourly AI summaries for today so far, yesterday, month to date, and recent completed days. sensor.power_ai_summary sends only allowlisted power meters and the read-only completed-day analysis to qwen3.8-27b on vLLM through authenticated LiteLLM. These are generated interpretations; the measured tiles and deterministic Findings remain the source of truth. No HA actions or equipment controls are exposed to the model.

The owning implementation is scripts/power-analysis/summary.py plus sensor.py in the Home Assistant app. Daily meter values require a local last_reset of today; yesterday comes from that meter's last_period. Month meters must belong to the current month. Missing data stays null. Consumers Energy yesterday values are withheld unless the reading date matches yesterday; month figures retain their separate reporting cutoff.

The existing 1Password litellm/master_key is projected by litellm-externalsecret.yaml into an optional, read-only Secret volume. The integration rereads the file each hour, allowing late secret creation or rotation without restarting HA. Missing credentials produce not_configured; timeouts, HTTP failures, or invalid model output produce error and clear the old text. Requests time out after 60 seconds and retry at the next hourly poll. The dashboard hides summaries from a different local date or more than two hours old. Summary text is excluded from recorder history.

After merging and the normal GitOps rollout, verify the ExternalSecret is Ready and sensor.power_ai_summary becomes ready, with today, yesterday, month, trends, as_of, and generated_at attributes. An unavailable recorder report should affect only the trend evidence; live meter summaries can still generate. For not_configured, inspect ExternalSecret status; for error, check HA and LiteLLM logs and backend health. Never print the Secret. The model's response format follows the vLLM chat-completion API. Rollback uses a revert PR and the same ConfigMap-driven rollout described above; no meter data or statistics need to be changed.

Retired completed-period statistics

The September 27 dashboard change removed state_class: total from 33 *_yesterday and *_last_month template sensors. These show completed-period snapshots, not accumulating meters. Their old recorder statistics metadata caused 33 "no longer has a state class" repair warnings.

The retire-period-statistics init container runs after configuration copying and the September 24 continuity repair, before Home Assistant starts. Its source is my-apps/home-automation/home-assistant/scripts/retire-period-statistics.py. It checks the exact 33 templates still lack a state class, archives their statistics metadata plus long- and short-term statistics, then removes only those retired series in one SQLite transaction. The archive must be durable before any deletion can commit. A missing database or previously completed cleanup is a no-op; unexpected configuration, source, or archive content stops the init container without deleting data.

Raw recorder states, active power/energy/cost meters, Consumers Energy statistics, and current template values are unchanged. Historical statistics for these 33 display sensors move out of the recorder into /config/statistics-repairs/retired-period-summaries-2026-09-29.json, on the kopiur-backed config PVC. The September 29 read-only export contained 8,877 long-term and 76,791 short-term rows; the archive was about 9 MB.

Rollout: merge the PR and let ArgoCD reconcile the hashed scripts ConfigMap. The existing Recreate strategy briefly stops HA while the init container archives the retired statistics. No live SQL or manual repair dismissal is needed. Before merging, verify the config PVC has a successful recent kopiur snapshot. After rollout, check:

kubectl -n home-assistant logs deployment/home-assistant -c retire-period-statistics
kubectl -n home-assistant rollout status deployment/home-assistant

The first run reports 33 metadata entries and the archived row counts; subsequent starts report zero. After HA's statistics validation runs, the 33 state-class warnings should disappear. Verify the Homelab Power dashboard still displays current and completed-period values. If initialization fails, inspect its error and preserve the archive; do not overwrite it to force a run.

Rollback: reverting the deployment change stops future cleanup but does not restore archived statistics. To restore them, use a separate GitOps PR changing this init container's command to ["python", "/opt/repo-scripts/retire-period-statistics.py", "--apply", "--restore"]. On the next Recreate rollout it restores the archive with HA stopped, assigning new row IDs where necessary. It is idempotent and refuses schema changes or conflicting existing statistics. Verify its success log, then remove the retirement init container in Git. The original warnings return unless the sensor configuration is also intentionally changed. Never run either apply mode inside the running HA container.

September 24 statistics repair

The recorder contains a verified discontinuity: hourly power statistics stop at 2026-09-24 14:00 UTC and resume at 23:00 UTC with their cumulative sum near zero, while meter state values continue increasing. For example, homelab energy goes from 247.005 to 252.296 kWh while its statistical sum drops from 104.892 to 0.309. This explains the negative daily bars and understated monthly graph. The first retained homelab cost statistic is September 16, so even after repair its September chart covers less time than the monthly meter tile. The dashboard labels this partial history. The available evidence establishes the statistics discontinuity; it does not establish which maintenance operation caused it.

The repo-owned scripts/repair-power-statistics.py initContainer runs while HA is stopped under the Deployment's Recreate strategy. It only considers the explicit power-entity pattern and the two exact hourly boundary timestamps. The offset is previous.sum + (next.state - previous.state) - next.sum. Both timestamps are on the same local day, with no daily, weekly, monthly or yearly cycle boundary between them. It adds that offset to subsequent long- and short-term sums; meter states, CE imports, and unrelated statistics stay unchanged. Surviving cumulative readings recover the day's total across the gap, but do not reconstruct when during those missing hours energy was used.

Before writing, it saves affected row IDs, timestamps and original sums in /config/statistics-repairs/power-2026-09-24.json, then updates in one SQLite transaction. Unexpected boundary data aborts the initContainer. A fresh installation or repaired database is a no-op. The September 27 read-only export yielded 130 repairable series; a local replay and repeat run verified the offsets and idempotence. No production database was changed during review.

After merge, verify the GitOps rollout and init logs:

kubectl -n home-assistant rollout status deployment/home-assistant
kubectl -n home-assistant logs deployment/home-assistant -c repair-power-statistics

Expected: a repair list and saved journal on the first rollout, then an empty repair list on later starts. Check the September 24 daily bars, monthly cost graph, and new dashboard tabs. CE comparison sensors may remain unavailable until the next successful utility import.

For a failure, retain the journal and inspect the init log. Do not delete the recorder database or zero the meters. A code revert does not undo a committed statistics repair. To undo, first use a PR to remove the repair initContainer and stop HA through GitOps (replicas: 0). With the PVC mounted by an approved maintenance workload and HA stopped, run the same repository script:

python /opt/repo-scripts/repair-power-statistics.py --apply --undo

This reverses the recorded offsets, including later rows that inherited the corrected baseline. It restores the original graph discontinuity. Restore replicas: 1 through a PR after checking the result. The journal is retained on the backed-up config PVC for inspection.

Resetting the history

Home Assistant keeps three kinds of state, and a "start fresh" has to clear all three or the old totals come back:

State Where How to clear
Recorder history + long-term statistics /config/home-assistant_v2.db (+ -wal, -shm) on the PVC Delete the files with HA stopped; it creates a fresh DB on start
Running totals of every integration and utility_meter sensor /config/.storage/core.restore_state Delete the file with HA stopped. HA rewrites it on every clean shutdown, so a kill -9 of the homeassistant process after deleting is what makes it stick
Grafana history Prometheus, 15-day retention Nothing to do; old series age out

Renaming an entity prefix is the same operation from Home Assistant's point of view: the new prefix starts at zero and the old one is orphaned.

Shed solar

panels → EPEVER XTRA3210N MPPT → 12.8 V LiFePO4 bank (2 × 100 Ah) → LOAD → Anker SOLIX → HP micro (Tapo Shed Lab)
                    │
                    └─ Modbus RTU over USB serial → rpi4 (192.168.10.174) → `epsolar` service

The rpi4 is the only host with the serial link. Its epsolar service (github.com/mitchross/epsolar, private) polls the controller every 5 s, runs the guarded LOAD automation, and serves two feeds:

Feed Consumer
:8080/metrics (epever_*, epsolar_*, solar_buffer_*) cluster Prometheus, job epever-solar (monitoring/metrics/prometheus-stack/values.yaml)
:8080/api/v1/status (JSON) Home Assistant rest: sensors sensor.solar_* / binary_sensor.solar_* (30 s)

Grafana: Solar (dashboards/home-energy/shed-solar.json), which mirrors HA's Solar view and keeps the epsolar controller internals in a collapsed row. Home Assistant: the Solar view of the Homelab Power dashboard. kWh counters are the controller's own lifetime totals.

The shed is off-grid, so keep it out of the HA Energy dashboard: that page models one house where solar feeds "Home", so adding solar_generated_total as a solar source or shed_lab_energy as a device inflates home consumption and shows 100 % self-sufficiency. The Energy dashboard is grid-only; the shed lives on the Solar view and the Grafana solar pages.

If the Pi is down every solar_* sensor goes unavailable and the Prometheus target shows up == 0; nothing on the grid side is affected.

Gaming sessions

binary_sensor.gaming_pc_gaming is on while the Gaming PC plug draws more than input_number.gaming_pc_active_threshold_w (350 W; idle is ~200 W, gaming gaming is 450–600 W) and turns off after five quiet minutes. Three template feeds are integrated only while it is on:

Sensor Meaning
sensor.gaming_pc_gaming_energy / _cost (+ daily/weekly/monthly/yearly meters) kWh and USD spent gaming
sensor.gaming_pc_gaming_hours (+ meters) hours gamed, from integrating a 1/0 flag, so it does not depend on recorder retention
sensor.gaming_pc_idle_cost_daily / _monthly the rest of the PC's cost: total minus gaming

Grafana Gaming PC (gaming-pc.json) and the Gaming view of the Homelab Power dashboard read these. The threshold is a slider so it can be tuned without a deploy; a permanent change goes in configuration.yaml.

AC cooling (modeled)

The central AC has no plug meter, so its cost is modeled, not measured: binary_sensor.ac_cooling is on while the Google Nest (climate.hallway_hallway) reports hvac_action: cooling (fan-only runs read fan and are not counted), and the runtime is priced at input_number.ac_cooling_wattage (placeholder 3500 W) × the live TOU rate — the same integration pipeline as the gaming sessions.

Sensor What it holds
sensor.ac_cooling_energy / _cost / _hours (+ daily/weekly/monthly/yearly meters) Modeled AC kWh, USD, and cooling hours
sensor.ac_cooling_cost_yesterday / _cost_last_month, _hours_*, _energy_last_month Finished periods, from last_period
sensor.ac_cost_per_cooling_hour Month-to-date USD per cooling hour
sensor.ac_share_of_house_yesterday AC cost as a % of the CE-billed house cost yesterday
sensor.ac_implied_watts_yesterday Calibration gauge: (CE house kWh − metered plugs − input_number.ac_house_baseline_kwh) ÷ cooling hours

Calibration loop: on 2–3 hot days with no dryer/oven/EV, compare ac_implied_watts_yesterday to ac_cooling_wattage; nudge the slider toward the median implied value, then commit it as initial: in configuration.yaml (Git is source of truth; the UI slider resets on HA restart). Month-end check: ac_cooling_cost_last_month + combined_* + baseline should land within ~10–15% of the CE bill; the wattage is an estimate (±20 % on a variable-speed unit). CE data is one day late, so every house comparison is yesterday-vs-yesterday. Because the 3 min delay_off over-counts runtime on short cycles, implied watts reads low on those days — calibrate from long, sustained cooling days.

Dashboards: the Cooling view of the Homelab Power dashboard and the AC tile on its House view; sensor.ac_* / binary_sensor.ac_cooling are in the Prometheus filter globs, so Grafana can read them.

Rolling findings and hardware comparisons

The Findings view uses sensor.power_spending_analysis, a local integration whose source is scripts/power-analysis/. It refreshes hourly after HA starts, reads the SQLite recorder in an executor thread, and is excluded from recorder history itself. The view is in lovelace-power-findings.yaml; the existing Overview remains the landing page.

The analysis uses the preceding 14 local days, excludes today, and requires a common set of complete hourly readings across the seven plug-energy series, homelab/office groups, detected gaming energy, and cooling hours. It needs the previous hourly boundary and matching CE daily energy/cost records. Missing hours, nonfinite values, counter discontinuities, and impossible gaming/runtime values exclude the day. Local-day length handles daylight saving transitions. This establishes recorded coverage; it cannot prove every physical sensor was accurate or responsive throughout the day.

Device ranking shows average watts and 720-hour projections at the current configured rate. Neither is an idle-only measurement or a full-month bill. Cooling correlation needs at least seven matched days and one hour of runtime variation. A fit against house energy minus computer energy is shown for investigation only. Its largest positive residual identifies a day to review; it cannot identify an appliance. The report does not change assumed AC wattage.

Use the power-analysis agent skill (shared procedure: .claude/commands/power-analysis.md) for repeatable analysis and safe accounting. The CLI emits the same report read-only; omit --rate to leave projections unpriced when the live configured rate is unknown.

Reassessing Threadripper vs the spare DL360

The owner's confirmed arrangement retains both RTX 3090s, using an external GPU PSU and PCIe risers with the DL360. Physical feasibility was established by prior use. Mink's historical compute inventory lists two E5-2680 v4 CPUs and conflicting RAM totals (736 GB, 724.24 GiB OS-visible, and approximately 768 GB physical claims); current installed CPUs and DIMMs still need verification. The separate NAS has one E5-2680 v4 and 384 GB, per the September 20 inspection. Do not substitute its power reading for the spare GPU server.

On September 27, a read-only trailing-24-hour Prometheus sample showed about 222.4 W at the Threadripper outlet (1,437 samples across HA pod changes) and 48.4 W combined GPU board power (5,760 samples per GPU). GPU utilization averaged about 0.3% per GPU across those samples. These clocks and measurement boundaries are close but different: the roughly 174 W difference includes CPU/RAM/drives, other host work, fans, and PSU losses. It is not a measured CPU-only idle figure or guaranteed removable overhead. The earlier 246.6 W average covers a different, eight-day cohort.

The first local Mink search found only an empty comparison note. The owner subsequently supplied historical chat extracts on September 27 with numerical readings. These are owner-reported historical observations; raw meter exports were not independently recovered. They support the earlier Threadripper move for the old dual-CPU DL360 configuration. A changed single-CPU arrangement still needs a new measurement. A matched comparison should include:

  • the same two GPUs, power caps, model, context, concurrency, and completed work;
  • all wall outlets including the external GPU supply;
  • both idle energy and Wh per inference workload, with tokens/sec and latency;
  • PCIe link width/speed under load and one-vs-two CPU memory/slot dependencies.

At $0.21328/kWh, saving 25/50/100 W continuously is $3.84/$7.68/$15.36 per 30 days. A low-power single-Xeon trial is a plausible candidate, not an established winner. More RAM helps when the workload needs it; the NAS has demonstrated ARC read benefits, while sustained and durable writes remain bounded by storage/network behavior. See NAS measurements, HPE DL360 Gen9 platform features, and TrueNAS caching and write behavior.

Historical power readings supplied by the owner

These records span different configurations and measurement boundaries. They are reference observations, not new live entities or values to backfill into recorder statistics.

Period and measurement Reported draw Boundary / limitation
February whole-basement plug ~571 W / 13.7 kWh/day Earlier configuration and all equipment on that feed
April post-tuning whole-rack trend ~620 → 520 → 484 W Attributed in the old account to low-power settings and GPU limits; not a controlled isolation of each change
May whole-rack Tapo 484 W mean/median; central 80% 472–498 W; p99 ~640 W Both servers, external supplies, switches and fan; p99 is not maximum
May Proxmox DL360 iLO 240 W average / 318 W peak Excludes external GPU supply; do not compare iLO directly with AC plug readings
May NAS iLO 85 W average / 139 W peak Old E5-2640 v3 / 160 GB configuration; drive PSU separate
June owner-reported plug averages DL360 host 259 W + GPU supply 66 W ≈ 325 W Dual E5-2680 v4, large RAM configuration; llama-swap unloading models
June owner-reported Threadripper plug average 246 W 2950X, 128 GB and both 3090s on one plug
June NAS plus drive PSU ~125–133 W Other dated accounts give host 77–82 W plus supply 48–51 W
September 5 audit snapshots Threadripper 182 W; NAS 114 W + drive PSU 43 W Threadripper had one GPU then; NAS later E5-2680 v4 / 384 GB
September 6 historical baseline Threadripper ~230–240 W, peak 764.7 W Second 3090 restored; baseline and peak are different statistics

The June host comparison is approximately 325 − 246 = 79 W in favor of Threadripper, or $12.13 per 30 days / $147.60 per 365-day year at the current configured $0.21328/kWh. The old reported NAS-inclusive totals (~452 versus ~371 W) give about 81 W because their components were rounded. These savings are repriced historical scenarios, not current utility-bill promises.

Another June 18 account reported host-only 334 W for DL360 and 135 W for Threadripper, plus a separate GPU feed at ~60 W settled or 230–450 W active. Adding those gives 394 versus 195 W settled, 564 versus 365 W at the lower GPU load, and 784 versus 585 W at the higher load. These are calculated alternatives for the SAME GPUs, not synchronized whole-system tests, and are not the same observation as the later 259/66/246 W averages.

The May allocation (205 W host, 125 W GPUs/supply, 110 W NAS/drives, 30 W network, 15 W fan) approximately reconciles the 484 W rack meter. Those allocations do not establish individually measured component watts or a universal 15% iLO error. The external PSU's 1,000 W rating is capacity, not draw.

Old summaries calling Threadripper retired or inferring a return to DL360 from stale August memory are superseded by the verified September Threadripper configuration. Likewise, historical "unmeasured desktop/mini" labels do not override their current HA plug readings. Keep the old NAS CPU/RAM configuration separate from today's E5-2680 v4 / 384 GB evidence.